Child pages
  • Dataflow
Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Current »

The description of the elements is followed by the description of their connections to each other, i.e. the dataflow. For ports connections the description starts with the .actor-bindings keyword and has the following format:

    .actor-bindings {
        element1_name.output_port1_name->element2_name.input_port2_name;
    }

This pair says that data from port1 of element1 will be transferred to port2 of element2. For slots the following format without start keyword is used:

element1_name.slot1_name->element2_name.port2_name.slot2_name

This pair says that data from slot1 of element1 will be transferred to slot2 of port2 of element2. See, for example, the minimum description of a dataflow of a workflow, that aligns an input MSA and writes the result to a file in ClustalW format.

    .actor-bindings {
        read-msa.out-msa->muscle.in-msa
        muscle.out-msa->write-msa.in-msa
    }
    read-msa.msa->muscle.in-msa.msa
    muscle.msa->write-msa.in-msa.msa

 

 

 

  • No labels